Low-voltage series
ATS
Abbreviation for ATS automatic transfer switch. ATS is mainly used in emergency power supply systems: a switching device that automatically transfers the load circuit from one power source to another (backup) power source, to ensure continuous and reliable operation of important loads. Under heavy load conditions, the transfer time is relatively long, over 100 ms, which will cause load power interruption; it is only suitable for ordinary lighting and ordinary motor loads. The ATS dual-power cabinet complies with the following standard: GB/T 7251.12 "Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies".
Request a quotePlease provide your operating conditions, quantity and required connection or output.
Technical details
Specifications from source material
Abbreviation for ATS automatic transfer switch. ATS is mainly used in emergency power supply systems: a switching device that automatically transfers the load circuit from one power source to another (backup) power source, to ensure continuous and reliable operation of important loads. Under heavy load conditions, the transfer time is relatively long, over 100 ms, which will cause load power interruption; it is only suitable for ordinary lighting and ordinary motor loads. The ATS dual-power cabinet complies with the following standard: GB/T 7251.12 "Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies".
- Rated operational voltage (Ue)
- V 380
- Rated operational current (In)
- A ≤1600
- Rated frequency (Fn)
- Hz 50
- Rated insulation voltage (Ui)
- V 660
- Rated short-time withstand current (Icw)
- kA 10, 30
- Rated peak withstand current (Icw)
- kA 17, 63
- Rated impulse withstand voltage (Uimp)
- kV 6
- Overvoltage category
- IV
- Pollution degree
- 3
- Electrical clearance
- ≥10 mm
- Creepage distance
- ≥12.5 mm
- Degree of protection
- (customizable for special requirements) IP30
- Dual-power cabinet
- Height (mm) 2200
Full product details
Overview
Abbreviation for ATS automatic transfer switch. ATS is mainly used in emergency power supply systems: a switching device that automatically transfers the load circuit from one power source to another (backup) power source, to ensure continuous and reliable operation of important loads. Under heavy load conditions, the transfer time is relatively long, over 100 ms, which will cause load power interruption; it is only suitable for ordinary lighting and ordinary motor loads. The ATS dual-power cabinet complies with the following standard: GB/T 7251.12 "Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies".
Operating Environment
Ambient air temperature not higher than +40°C and not lower than -5°C. The average temperature within 24 h shall not be higher than +35°C. For indoor installation and use, the altitude of the installation site shall not exceed 2000 m. The relative humidity of the ambient air shall not exceed 50% at a maximum temperature of +40°C; higher relative humidity is permitted at lower temperatures, for example 90% at +20°C, but occasional condensation may occur due to temperature changes. During installation, the inclination from the vertical shall not exceed 5°. The equipment shall be installed in locations free from severe vibration and shock, and where electrical components are not easily subject to corrosion. *Note: If the user has special requirements, these can be resolved through consultation with the manufacturer.
Technical Parameters
Rated operational voltage (Ue): V 380; Rated operational current (In): A ≤1600; Rated frequency (Fn): Hz 50; Rated insulation voltage (Ui): V 660; Rated short-time withstand current (Icw): kA 10, 30; Rated peak withstand current (Icw): kA 17, 63; Rated impulse withstand voltage (Uimp): kV 6; Overvoltage category: IV; Pollution degree: 3; Electrical clearance: ≥10 mm; Creepage distance: ≥12.5 mm; Degree of protection: (customizable for special requirements) IP30
Dimensions
Dual-power cabinet: Height (mm) 2200; Width (mm) 600~1200; Depth (mm) 600~1000
Product Features
The main wiring arrangements for dual-power supply include double radial, double trunk, and common standby trunk arrangements. Double radial wiring: In the double radial wiring arrangement, each user is supplied by two radial lines, and both lines are supplied by independent power sources; when one line fails or loses power, the user can maintain supply from the other line, so this wiring arrangement has high supply reliability and is mostly used to supply important loads with relatively large capacity. Double trunk wiring: In the double trunk wiring arrangement, each user is supplied by two trunk lines from different power sources; for each user, this is dual-power supply, so supply reliability is greatly improved. It can be used to supply important loads of not too large capacity that are far from the supply point. Common standby trunk wiring: In the common standby trunk wiring arrangement, each user is supplied by a single radial line and at the same time obtains standby power from a common standby trunk; for each user, dual power can be obtained, which saves investment and reduces consumption of non-ferrous metals. It can be used to supply multiple important loads of not too large capacity. The degree of protection of the cabinet is generally IP30; users may also choose between IP30 and IP42 according to the requirements of the operating environment.